PID controller( temperature PID controller, pressure PID controller)
Detailed Product Description
PID controller( temperature PID controller, pressure PID controller)
PID controller
INPUT SIGNAL
analog input: resistancedifferent heat resistance, such as Pt100,Cu100,
Cu50 or remote pressure resistance
thermocoupledifferent thermocouples, such as B, S, K, E, J, T, WRe
voltage05V,15V or mV, and so on
current010mA,420mA or 020mA,and so on
pulse input: wave spectrumrectangularsinusoidal or triangle
voltagemore than 4V(or by user)
frequency05KHz..
MEASURE RANGE 19999999 digit
MEASURE ACCURENCY 0.2%FS±1digit or 0.5%FS±1digit
RESOLUTION ±1digit
TEMPERATURE COMPENTATION 050
DISPLAY METHOD
19999999 Display measured value 19999999 Display set value..
19999999 Display external given value19999999 Display value position feedback value.
0100% Display output Display LED working state
Display LED working state Display highlighted LED digits
CONTROL METHOD
PID control current/voltage output PID control relay switch output
Position ON/OFF with back-difference
SWITH OUTPUT relay positive/inverse turn control outputrelay ON/OFF with back-difference
OUTPUT SIGNAL
Analog output: 010mA(load resistance≤750Ω)
420mA(load resistance≤500Ω)
05V(output resistance≤250Ω)
15V(output resistance≤250Ω)
Switch output: relay control output(AC220V/3A,DC24V/5A,resistance load)
relay positive/inverse turn control outputrelay ON/OFF with back-difference
contact capacity:AC220V/3A; DC24/6A(resistance load)
Controllable silicon control outputSCR (controllable silicon zero contact pulse,400V/0.5A
Solid relay outputSSR(Solid relay control signal)output,624V/30mA
Feed power output: DC24V, load≤30mA
Communication output:
portstandard serial bi-direction communication port:RS-485,RS-232C,RS-422
baud rate3009600bps internal setting at will
Analog control output is isolated from transducer output
ALARM METHOD
Can select relay higher/lower limit alarm output, LED indication
Can select relay highest limit alarm output, LED indication
Can select relay lowest limit alarm output, LED indication
Can select relay within deviation limit alarm output, LED indication
Can select relay beyond deviation limit alarm output, LED indication
Can select relay LBA limit alarm output, LED indication
ALARM ACCURACY ±1digit
COMMUNICATION
Communication protocol can be two, three or four wire system (such as RS-485, RS-323,RS-422),or can be assigned by user. band rate 3009600bps can be set by internal parameters at will. Interface is isolated from mainframe by photo-electricity to improve system reliability and data security. The maximum communication distance is 1 km.Upper microcomputer can collect various signals and data to from energy managing and controlling system. Using SWP data collector and SWP NUBAN industrial control configuration software, several GN instruments can be on-lin e communicated with one or more microcomputers. The system uses main-subordinate type of communication to from various energy managing and controlling systems. The control loop only needs one two-wire(or three-or four-wire)cable to communicate with upper microcomputer, which can call the device number set by user, call on-line data of instruments at any time, and set internal parameters
PRINT CONTROL directly connect with different serial printer, communication method is RS-232
PRINT ACCURACY the same as the instrument measuring accuracy
SETTING METHOD
Front panel touch keypad digital setting
Keep set values permanently if power breaks down
Lock passwords of parameters set values
PROTECTION METHOD
Input loop break alarm (relay output, LED indication)
Alarm when surpass or under range(relay output, LED indication)
Automatic recovery when under normal voltage
Automatic recovery when abnormal operating(Watch dog)
OPERATING ENVIRONMENT Ambient Temperature 050
Relative Humidity≤85 RH
Power SupplyNormal: AC220V+10-15%(50Hz±2Hz,linear power supply)
Special: AC90260VSwitching power supply
DC24V±2VSwitching power supply
Avoid heavy corrodent gas
POWER CONSUMPTION
≤5W(AC 220V power supply)
≤4W(AC90265V Switching power supply)
≤4W(DC24V power supply)
CONSTRUCTION Standard Inserting Type
WEIGHT 420g(AC power supply)
260g(Switching power supply)......